270 Upgrade and Maintenance Manual RX4770 M1
Front panel and Chassis ID
13.2 Chassis ID
13.2.1 Replacing the Chassis ID
Note on system information backup / restore
I The Chassis ID EPROM contains system information like server name
and model, housing type, serial number and manufacturing data.
To avoid the loss of non-default settings when replacing the system
board, a backup copy of important system configuration data is
automatically stored from the system board NVRAM to the Chassis ID
EPROM. After replacing the system board the backup data is restored
from the Chassis ID board to the new system board.
V CAUTION!
For that reason the Chassis ID and system board must not be replaced
simultaneously! In this case, restoring the system configuration data on
the system board would fail.
13.2.1.1 Preliminary steps
Ê "Suspending BitLocker functionality" on page 59
Ê "Disabling SVOM boot watchdog functionality" on page 60
Ê "Locating the defective server" on page 43
Ê "Shutting down the server" on page 46
Ê "Disconnecting power cords" on page 46
Ê "Getting access to the component" on page 48
Ê "Removing memory boards" on page 220
Ê "Removing the fan box" on page 127
Field Replaceable Unit
(FRU)
Hardware: 10 minutes
Software: 5 minutes
Tools: Philips PH2 / (+) No. 2 screw driver

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu Primergy RX4770 M1 and is the answer not in the manual?

Fujitsu Primergy RX4770 M1 Specifications

General IconGeneral
BrandFujitsu
ModelPrimergy RX4770 M1
CategoryServer
LanguageEnglish

Related product manuals