Page #112 background imageLoading...
Page #112 background image
112 Upgrade and Maintenance Manual RX4770 M1
Hard disk drives / solid state drives
7.3 Removing 2.5-inch HDD / SSD / PCIe SSD
modules
I The preliminary and concluding steps are only necessary for HDD / SSD
modules not for PCIe SSD modules. PCIe SSD modules are never
combined in a RAID array.
7.3.1 Preliminary steps
Ê If the HDD / SSD module to be removed is combined into a RAID array,
please proceed as follows:
Customer Replaceable Unit
(CRU)
Hardware: 5 minutes
Tools: tool-less
RAID level Procedure
RAID 0
Only remove an HDD module combined in a RAID 0 array if
defective.
V CAUTION!
Removing an operational HDD module will result
in data loss!
RAID 1
RAID 5
Removing an HDD module from a RAID 1 or RAID 5 array
will not result in data loss.
However, the removed drive needs to be replaced
immediately by an HDD module of the same or larger
capacity.
I After replacing the HDD module, RAID rebuild will
be performed as a background process as
described in section "Performing a RAID array
rebuild" on page 81.

Table of Contents