229
────────────────────────────────────────────────────
11.4 Command Reference
────────────────────────────────────────────────────
PT ratio setting
Synta
x
SCALe:PT data
dat
a
1 to 10000 (numerical value in NR1 format)
Functio
n
The current value of PT ratio is set.
Not
e
If data is other than character data, a command error is generated.
Setting the averaging count.
Erro
r
If the value other than setting limit is set, an execution error is generated.
If an attempt is made to execute this command while waiting for or
executing integrated measurement or demand measurement, a device-
dependent error results.
Exampl
e
Transmission
":SCAL:PT 1"
The PT ratio is set to 1.
PT ratio setting query
Synta
x
SCALe:PT?
Functio
n
The current value of PT ratio is returned as a numerical value (data)in
NR1 numerical format.
Respons
e
synta
x
If headers are ON
If headers are OFF
":SCALE:PT data"
"data"
Exampl
e
If headers are ON
If headers are OFF
Transmission
Response
":SCAL:PT?"
":SCALE:PT 1"
":SCAL:PT?"
"1"
S
CALe:PT
S
CALe:PT?