2. In the Drop Detector Calibration submenu, select Calibrate Drop Detector and press OK.
3. When the following message appears on the front panel, press OK to continue with the calibration, or
press Cancel to exit.
4. The printer will start to calibrate the Drop Detector, which takes about 1 minute.
5. Once the Drop Detector has been calibrated, the results are displayed on the front panel.
The offset is the displacement from the nominal Carriage position for drop detection. The window width
refers to values captured by the drop detector sensor. The offset should be within the valid range, and
the window width should be at least the minimum shown. If the values are correct, press OK to accept
them. If not, the Drop Detector is not correctly installed, either because the Service Station has not been
correctly installed in the Scan Axis or because the Drop Detector is not correctly installed or not working
properly. Press Cancel to reject the values.
CAUTION: Do not accept these values if they are not within the right range, as the printer will not work
properly.
6. Press OK to end the calibration.
ENWW Entering the Service Calibrations menu 119