9. The front panel shows the actual right offset value and then the right alignment position.
10. The calibration process continues, and the front panel shows the new nominal offset value. Press OK to
continue.
11. When the calibration is complete, the result is displayed on the front panel. Press OK to leave the
calibration process.
12. Replace the Right Cover See Cover, Right on page 213.
Reset vacuum calibration
The purpose of this Service Calibration is to reset the nominal values of the Vacuum Calibration.
NOTE: Reset the vacuum calibration only if the vacuum fans are working (the printer can turn them on
without system errors), but the vacuum pressure is incorrect and there are carriage crashes. The existing
calibration will be lost.
Reset the vacuum calibration as follows:
1. In the Service Calibrations submenu, select Vacuum Calibration and press OK.
2. When the following message appears on the front panel, press OK to continue, or press Cancel to exit.
128 Chapter 6 Service calibrations ENWW