3. The front panel asks for confirmation. If you are sure that you want to reset the calibration, press OK to
continue, or press Cancel to exit.
4. The printer resets the nominal values of the Vacuum Calibration. If all goes well, an acknowledgement
is displayed.
5. Press OK to return to the menu.
Platen blue line calibration
The purpose of this Service Calibration is to calibrate the blue line that is marked on the Print Platen.
You should calibrate the blue line whenever the Center Platen is disassembled or replaced.
1. If paper is loaded in the printer, unload it.
2. In the Service Calibrations submenu, scroll to āPlaten blue line calib.ā and press OK.
3. When the following message appears on the front panel, you can press OK to continue with the
calibration, or Cancel to exit.
ENWW Entering the Service Calibrations menu 129