SE 17.0:11
Cause: PrintMech to Interconnect Power cable does not seem to be connected
Solution: Try the following.
●
Check that the PrintMech to Interconnect Power cable is not damaged.
●
Check that the PrintMech to Interconnect Power cable is correctly connected to the PrintMech PCA and
the Interconnect PCA.
●
Replace the PrintMech to Interconnect Power cable (which is included in the Electronics Module Cable
Kit).
SE 17.1:11
Cause: PrintMech to Interconnect Data 1 cable does not seem to be connected
Solution: Try the following.
●
Check that the PrintMech to Interconnect Data 1 cable is not damaged.
●
Check that the PrintMech to Interconnect Data 1 cable is correctly connected to the PrintMech PCA and
the Interconnect PCA.
●
Replace the PrintMech to Interconnect Data 1 cable (which is included in the Electronics Module Cable
Kit).
SE 17.2:11
Cause: PrintMech to Interconnect Data 2 cable does not seem to be connected
Solution: Try the following.
●
Check that the PrintMech to Interconnect Data 2 cable is not damaged.
●
Check that the PrintMech to Interconnect Data 2 cable is correctly connected to the PrintMech PCA and
the Interconnect PCA.
●
Replace the PrintMech to Interconnect Data cable 2 (which is included in the Electronics Module Cable
Kit).
SE 17.3:11
Cause: Main PCA to PrintMech Black 1 cable does not seem to be connected
Solution: Try the following.
●
Check that the Main PCA to PrintMech Black 1 cable is not damaged.
●
Check that the Main PCA to PrintMech Black 1 cable is correctly connected to the Main PCA and the
PrintMech PCA.
●
Replace the Main PCA to PrintMech Black 1 cable (which is included in the Electronics Module Cable Kit).
SE 17.4:11
Cause: Main PCA to PrintMech Blue 2 cable does not seem to be connected
Solution: Try the following.
44 Chapter 3 System error codes ENWW