Enter the front panel menu and retry the printhead alignment.
●
If the printhead alignment fails again, check the alignment pattern to see whether any of the
printheads are printing incorrectly. If necessary, perform a printhead recovery through the front
panel and retry the printhead alignment.
11. When the whole Line Sensor calibration is completed successfully, the following message is displayed.
Calibrate Rewinder
The purpose of this Service Calibration is to calibrate the printer's Rewinder Motor parameters.
To perform this test, first load an empty spindle on the printer, then the printer will start a set of movements
to characterize and calibrate the motor.
1. Select Calibrate Rewinder from the Calibrations menu.
2. The front panel prompts you to load an empty spindle on the printer.
3. The front panel displays a message while perfoming rewinder calibration.
4. If the calibration completes successfully, the front panel shows the result and prompts you to press OK
to save values; or Cancel if you prefer not to save values.
5. If the calibration fails, the front panel displays the reason.
Primer calibration
The purpose of this Service Calibration is to compute the optimum position of the Primer Assembly with
respect to the Carriage.
The calibration is a visual procedure, so you will have to remove the Right Cover before starting.
Perform the Primer Assembly as follows: