17. When the calibration has finished, the front panel displays the results. In the example below, each value
passes the test. Press OK to continue.
18. The front panel confirms the success or failure of the calibration. Press OK to continue.
If the calibration fails for any reason, try the following suggestions in order. If one suggestion solves the
problem, there is no need to continue to the next.
1. Repeat the OMAS Calibration process from the beginning.
2. Replace the OMAS Sensor and repeat the calibration
See Optical Media Advance Sensor (OMAS)
on page 340.
3. Replace the OMAS Controller Card and repeat the calibration
See OMAS Controller Card on page 349.
4. Replace the Media-Axis Motor and repeat the calibration
See Media-Axis Motor on page 313.
ENWW Entering the Service Calibrations menu 135