Operation Manual – MSTP
Quidway S5600 Series Ethernet Switches-Release 1510 Chapter 1
MSTP Configuration
Huawei Technologies Proprietary
1-34
Caution:
Among loop prevention function, root protection function, and edge port setting, only
one can be valid on a port at one time.
1.5.2 Prerequisites
MSTP runs normally on the switch.
1.5.3 BPDU Protection Configuration
I. Configuration procedure
Table 1-30 Enable the BPDU protection function
Operation Command Description
Enter system view
system-view
Enable the BPDU
protection function
stp bpdu-protection
Required
The BPDU protection function
is disabled by default.
II. Configuration example
# Enable the BPDU protection function.
<Quidway> system-view
[Quidway] stp bpdu-protection
1.5.4 Root Protection Configuration
I. Configuration Procedure
Table 1-31 Enable the root protection function in system view
Operation Command Description
Enter system view
system-view
Enable the root
protection function
on specified ports
stp interface interface-list
root-protection
Required
The root protection function is
disabled by default.