Operation Manual – Login
Quidway S5600 Series Ethernet Switches-Release 1510 Chapter 2 Logging in through the Console Port
Huawei Technologies Proprietary
2-10
Operation Command Description
Set the maximum
number of lines the
screen can contain
screen-length
screen-length
Optional
By default, the screen can contain up
to 24 lines.
You can use the screen-length 0
command to disable the function to
display information in pages.
Set history command
buffer size
history-comman
d max-size value
Optional
The default history command buffer
size is 10. That is, a history command
buffer can store up to 10 commands
by default.
Set the timeout time
for the user interface
idle-timeout
minutes
[ seconds ]
Optional
The default timeout time of a user
interface is 10 minutes.
With the timeout time being 10
minutes, the connection to a user
interface is terminated if no operation
is performed in the user interface
within 10 minutes.
You can use the idle-timeout 0
command to disable the timeout
function.
Note that the level the commands of which are available to users logging into a switch
depends on both the authentication-mode password and the user privilege level
level command, as listed in the following table.
Table 2-7 Determine the command level (B)
Scenario
Authentication
mode
User type Command
Command
level
The user privilege level
level command is not
executed
Level 3
Local authentication
(authentication-m
ode password)
Users logging in
through the
AUX user
interface
The user privilege level
level command is
already executed
Determined
by the level
argument