v Target 2 - IP Address - Enter an optional second IP address where SNMP traps are sent, or leave as
0.0.0.0.
v Target 3 - IP Address - Enter an optional third IP address where SNMP traps are sent, or leave as
0.0.0.0.
v Version - The library offers three versions of the SNMP protocol; v1, v2, and v3. Select a version for
each Target IP address.
v Audit Logging - If SNMP is enabled and Audit Logging is enabled, the library sends SNMP traps to
an SNMP Management console when the library or tape drive configuration changes.
Note: This option is available only if the library firmware is 9.00 or higher, and the latest library MIB
file is added to the SNMP Management console.
SNMP V3 SECURITY
v User Name - Enter your preferred name, or leave as "initial".
v Authentication - The options for Authentication are none, MD5, or SHA.
v Authentication Password - The Authentication Password must be at least 8 characters in length. If
Authentication is set to none, this field and the Privacy and Privacy Password fields are disabled.
v Privacy - The options for Privacy are none, or DES. If Privacy is set to none, then the Privacy
Password field is disabled.
v Privacy Password - The Privacy Password must be at least 8 characters in length.
Note: The factory default settings for SNMP V3 Security are
v User Name - initial
v Authentication - none
v Privacy - none
Configure Library: Save/Restore
This page allows the library configuration to be reset to the factory defaults.
For information about factory default settings, see “Configure: Save/Restore” on page 105. When you
restore your library to factory defaults, all configuration data in the library is lost and must be
reestablished. Feature Activation Keys is retained.
Saving and restoring configuration data can be done with the Remote Management Unit (RMU) or the
Operator Control Panel (OCP). The feature is implemented on the RMU and on the OCP, but with
slightly different functionality.
Note: Configuration files saved with one version of library firmware might not be compatible with other
versions of firmware. It is recommended to save a configuration file each time the library firmware is
upgraded. Restore the library with a configuration file that was saved with the same version of firmware
that is currently installed in the library.
Since the RMU can be accessed remotely, its implementation saves or restores the configuration data to or
from a file on the host site. When commands on the OCP are entered, the unit is accessed directly. For
this reason the OCP implementation saves or restores the configuration data to or from a USB flash drive
that is inserted into the USB connector on the library controller.
150 IBM TS3100 Tape Library and TS3200 Tape Library: Setup, Operator, and Service Guide Machine Type 3573

Table of Contents

Other manuals for IBM TS3100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM TS3100 and is the answer not in the manual?

IBM TS3100 Specifications

General IconGeneral
BrandIBM
ModelTS3100
CategoryNetwork Hardware
LanguageEnglish

Related product manuals