Table 17. Operation specifications: Ultrium 3 (continued)
Library with
Ultrium 3 drive(s)
2U library 4U library
Interfaces
Ultra160 SCSI LVD
4 Gb/s Fibre Channel
Ultrium 3 HH SAS Drive V2 (6 Gb/s)
3 Gb/s SAS
Environmental specifications
Table 18. Environmental specifications
Temperature
Operating 10° to 35° C (50° to 95° F)
Storage, without cartridges -30° to 60° C (-22° to 140° F)
Wet bulb, operating 26° C (79.0° F) maximum
Temperature shock immunity - maximum rate of change 10° C (18° F) per hour
Miscellaneous
Dust concentration less than 200 microgram/cubic meter
Altitude (operating) 2500 meters (8200 ft.) at 25°C ambient
Maximum acoustical noise sound power levels LwAd in bels 6.6/6.8
Humidity
Operating 15% to 80% RH non-condensing
Storage, without cartridges 10% to 90% RH non-condensing
Product environment
The library is designed to operate in a general business environment.
The library meets the acoustical requirements for general business area category 2D. Category 2D states
that the library should be installed a minimum of 4 m (13 ft.) from a permanent work station.
To allow for service access, install the library a minimum of 0.9 m (3 ft.) from all obstacles.
The library is a precision computer peripheral device. To ensure maximum longevity of your library,
locate the library away from dust, dirt, and airborne particulates:
v Keep the library away from high-traffic areas, especially if the floor is carpeted. Carpeting harbors dust
and walking on the carpet can cause the carpet fibers and the dust to become airborne.
v Keep the library out of printer/copier rooms because of toner and paper dust. Additionally, do not
store paper supplies next to the library.
v Keep the library away from moving air caused by doorways, open windows, fans, and air
conditioners.
Ensure that the machine covers are always kept closed to minimize any contamination from airborne
particles.
Supported servers, operating systems, and software
The library is supported by a wide variety of servers (hosts), operating systems, and adapters. These
attachments can change throughout the life cycle of the product.
Product description 15

Table of Contents

Other manuals for IBM TS3100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM TS3100 and is the answer not in the manual?

IBM TS3100 Specifications

General IconGeneral
BrandIBM
ModelTS3100
CategoryNetwork Hardware
LanguageEnglish

Related product manuals