Error codes
If an error occurs during operation of the library, the library stops the current operation and displays an
error code on the LCD screen. Unless otherwise noted in “Error codes,” try to resolve the error by cycling
power to the library and retrying the last operation. If the error persists, contact technical support.
Example error code
EVENT -6
8D 07
Where:
v -6 indicates the position in sequence list, 0 being the most recent.
v 8D 07 indicates the error. (code 8D = sled blocked,).
The event log with the library also includes a date stamp for each event. Press SELECT to display the
associated time stamp in the following format:
yy.mm.dd hh:mm:ss:HH
Where:
v yy is the year
v mm is the month
v dd is the current day
v hh is hours
v mm is minutes
v ss is seconds
v HH is 1/100 second
The time stamp is set to zero at system start.
A description of each error code and possible solution is provided in “Error codes”.
Preparing to resolve an error code
1. Record the error information that is displayed on the Operator Control Panel display or Web User
Interface screen.
2. If possible, cycle library power and retry the operation.
v If the error recurs, refer to “Error codes” for information about resolving the error.
v If the error does not recur, run Library Verify before normal library operation is continued.
Complete the steps in “Preparing to resolve an error code” before you complete the User Action listed in
“Error codes.”
Error codes
Errors that are described are hard errors. If such an error occurs the library stops all operations and the
Error LED starts flashing. An appropriate message is posted on the Operator Control Panel and the Web
User Interface. These errors are also reported by way of email notification, if enabled. To enable email
notifications, refer to “Configure Library: Event Notification” on page 148.
© Copyright IBM Corp. 2007, 2018 201