INSTRUMENTS (AND AVIONICS) / INSTRUMENTS AND AVIONICS GENERAL MAINTENANCE 13-25
CHANGE C2 ICON A5 / MAINTENANCE MANUAL
VERIFICATION METHOD:
1) Turn the master switch on. Verify that the fuse does NOT light up.
2) Check the correct function of the system associated with the replaced fuse.
RELATED INFORMATION:
"Landing Gear Actuator Fuse Blown" on page 14-15
13.3.3 Calibrate AOA Pressure Transducer
The following section contains the information necessary to perform the calibration of the AOA pres-
sure transducer.
TASK INFORMATION:
Type of Maintenance
Line
Level of Certification
LSA-RM
Task Specific Training Required
No
Special Tools Required
None
Parts Required
None
Aircraft System and Number
10—Instruments (and Avionics)
Consumables
None
1. Turn on the master switch (or confirm on).
2. Locate the calibration push button switch on the bottom side of the MSC computer.
NOTE: The MSC computer is located behind the right hand crossbeam
and can be reached through the passenger footwell.
3. Press button and hold for 5 seconds.
NOTE: During this time, an LED next to the switch will flash at a 2 Hz rate
and flashes a GREEN indicator.