INSTRUMENTS (AND AVIONICS) / INSTRUMENTS AND AVIONICS GENERAL MAINTENANCE 13-25
CHANGE C2 ICON A5 / MAINTENANCE MANUAL
CHAPTER 13
VERIFICATION METHOD:
1) Turn the master switch on. Verify that the fuse does NOT light up.
2) Check the correct function of the system associated with the replaced fuse.
RELATED INFORMATION:
"Landing Gear Actuator Fuse Blown" on page 14-15
13.3.3 Calibrate AOA Pressure Transducer
The following section contains the information necessary to perform the calibration of the AOA pres-
sure transducer.
TASK INFORMATION:
Type of Maintenance
Line
Level of Certification
LSA-RM
Task Specific Training Required
No
Special Tools Required
None
Parts Required
None
Aircraft System and Number
10—Instruments (and Avionics)
Consumables
None
TASK INSTRUCTIONS:
1. Turn on the master switch (or confirm on).
2. Locate the calibration push button switch on the bottom side of the MSC computer.
NOTE: The MSC computer is located behind the right hand crossbeam
and can be reached through the passenger footwell.
3. Press button and hold for 5 seconds.
NOTE: During this time, an LED next to the switch will flash at a 2 Hz rate
and flashes a GREEN indicator.