iPECS eMG80 & eMG800 & UCP
Feature Description and Operation Manual Issue 1.6
78
use Accept or Deny when notified of the conference.
1. Press the Monitor flex button, the state of the first member is displayed.
To monitor conference member status or delete members while in the conference
2. Press [VOL UP/VOL DOWN] button to display the state of other members.
3. Press the [DND] button to delete a participant from the conference.
1. Press the [TRANS/PGM] button.
To monitor the Group member conference status while Not in the conference
2. Dial “551”, the Monitor Conference Group code.
3. Press [VOL UP/VOL DOWN] button to display the state of other members.
1. Press the [HOLD/SAVE] button to place the conference on hold.
To add a non-member to the Group
2. Call the desired party.
3. Press the [CONF] button.
Conditions
1. The conditions associated with Multi-Party Voice Conference apply.
2. Members using the iPECS UCS client Soft phone may view the state of other
members in the conference.
3. A maximum of 20 (eMG80) and 100 (eMG800/UCP) Station Conference Groups can
be created by any system user and 40 (eMG80) and 160 (eMG800/UCP) System
Conference Groups can be created in iPECS system.
4. The user must have access to the Station Web Admin with the proper password
(Authentication code).
5. If there are insufficient Conference channels available when initiating the conference
group call, the initiator receives error tone.
6. Two-way record can be used to record the Conference Group call.
7. eMG80/800 can’t support Conference recording.
8. For iPECS UCP, MCIM is required to support 32 party conferences. With the MCIU,
the number of parties in the conference cannot exceed the number of MCIU channels .
2 channels of each MCIU/MCIM is reserved for link with other MCIU/MCIM.
Programming
Related Features
Multi-Party Voice Conference
Conference Room
System Admin Programming
Hardware