ID Index Name / Setting Unit Description
0:PressCon Max.pressurevaluefromHYD_PressCon_pMax
1:Pos_pRef Max.pressurevaluefromHYD_Val_pRef
2:Neg_pRef Max.negativepressurevaluefromHYD_Val_pRef
2840 6 QMinSrc Minimumflowratesourceselector
0:PressCon Min.pressurevaluefromHYD_PressCon_QMin
1:Neg_QRef Min.pressure,negativevaluefromHYD_Val_QRef
2:Pos_QRef Min.pressurevaluefromHYD_Val_QRef
2840 7 QMaxSrc Maximumflowratesourceselector
0:PressCon Max.volumeflowvaluefromHYD_PressCon_QMax
1:Pos_QRef Max.volumeflowvaluefromHYD_Val_QRef
2:Neg_QRef Max.negativevolumeflowvaluefromHYD_Val_QRef
2840 8 QActCalc Flowratecalculationmethod
0:MEAS Fromthemeasurement
1:CYL Fromthecylinderspeed
2840 9 QLeakEst Flowrateleakageestimationmethod
0:NONE Noleakagecompensation
1:OBS Observer
2:MEAS Directlymeasured
3:CTRL PIcontroller
2840 10 nRefSrc Pumpspeedreferencesourceselector
0:ANA Setpointfromprofile
1:PROFILE Referencevaluefromprofile
2840 11 CylValveSwSel Functionselectorforthevalveswitchoverofthecylinder
0:Para Manualvalvecontrol
1:Spd Automaticvalveswitchoverviaspeedsetpoint
2:Tab Valveswitchoverviamotionblocktable
3:Pos AutomaticvalveswitchingviaPos.Diff.
2840 12 AltPosCon Alternativepositioncontroller
2840 13 AltSpdCon Alternativecylinderspeedcontrollers
2840 14 PumpSpdProt Pumpspeedprotection
2840 15 PumpP2tProt p2tprotectionforpump
2840 16 AltPressCon Alternativepressurecontroller
2840 17 AltPressConLimit Alternativepressurelimitcontroller
Table 7.52: “Selection of signal sources” parameters (continue)
ID No.: 0842.26B.5-01Date: 09.2020
ServoOne- Device Help
183
7 Control
7.11.3.2Signalscaling
7.11.3.2.1Signalscaling,pressure
Image 7.57: “Hydraulic signal scaling, pressure” screen
P2845 - HYD_Input_Val will show the unscaled pressure reference and actual
values for the pressure control.
Further processing and scaling is carried out in P2846 - HYD_Input_Adapt. A
scaling factor, an offset, and a signal limit (min and max) can be set.