Remote RMX-3200 Version 5.2x Configuration Guide
Configuring Mediation Connections: Configuring an Asynchronous Serial to Asynchronous Serial
Connection
17-12
5. (optional) At the main prompt, configure controller serial 1 with application
mode
destination:
config controller serial 1 application destination
Note: By default, asynchronous serial controllers are configured to act as both
sources and destinations for connections, which makes configuration of
this command optional.
6. (optional) Configure connection mode
activity:
config controller serial 1 connect mode activity
7. Configure controller serial 2 application mode as source:
config controller serial 2 application source
8. Configure connection mode dcd:
config controller serial 2 connect mode dcd