Remote RMX-3200 Version 5.2x Configuration Guide
Configuring Controllers and Interfaces: Configuring T1/E1 Line Encapsulation Settings
7-10
13. (optional) Verify that the encapsulation settings on controller serial wan/2 have
been configured properly:
show controllers serial wan/2
The command response similar to the following displays (for a T1 controller):
14. Save the configuration.
(Dub)>show controllers serial wan/2
serial wan/2 status=enabled
resource-state=unassigned
rx-link-state=LOF
tx-link-state=up
local-loop=norm
remote-loop=norm
buildout=-7.5dB
clock=loop
framing=d4
linecode=b8zs
framer-crc-errors=0
framing-errors=403315940
line-coding-violations=0
severely-errored-framing-events=0
desc=T1 port
channel-group=group status=enabled
system-name=hdlc0
speed=64
encap=hdlc
timeslot=1-5,7-16
(Dub)>