MD-11 Flight Crew Operations Manual
k
Electrical -
Description and Operation
Elec.10.4
The respective GCU (1, 2, 3, and APU) regulates the following:
IDG and APU generator voltage.
IDG frequency and current limit.
IDG load control.
Each GCU (1, 2, 3, and APU) protects its respective generator from electrical
faults.
The respective GCU (1, 2, 3, and APU) provides automatic operation of:
IDG reset due to generator protective trips.
ac generator bus 1, 2, and 3 fault reset.
Maintaining IDG oil temperature and pressure indication for IDG fault
indicating.
Electrical Power Control Unit (EPCU)
The EPCU controls the following:
•EPR.
•BTR-EP.
Ground Service Relay (GSR) - external power position.
Auxiliary Power Relay (APR) 1, 2, and 3.
Load shedding.
APU N2 speed for APU NBPT operation.
NBPT from external power to APU generator.
NBPT from IDG to external power across BTR-EP.
NBPT from IDG to APU generator.
DUAL LAND mode electrical system configuration.
Electrical Power System (EPS) operating mode.
EPS parameter transmission to EIS.
EPS fault transmission to the CFDS.
Frequency reference for GCU 1, 2, and 3.
Galley Transfer Relay (GTR) 1, 2, and 3.
The EPCU provides protection for the following:
Main external power phase sequence.
Main external power over/under voltage.
Main external power over/under frequency.
Main external power feeder fault.
ac tie bus fault.
If galleys are installed, galley external power voltage, frequency and
phase sequence.
The EPCU provides automatic operation of the following:
APU generator reset for incorrect voltage, frequency or feeder faults.
October 02, 2006