MD-11 Flight Crew Operations Manual
k
Fire Protection -
Controls and Displays
Fire.30.8
4. FIRE AGENT DISCHARGE Switch (2)
The DISCHARGE position will discharge the respective fire agent bottle to
the APU compartment if the APU OFF AGENT ARM switch is in the APU
OFF AGENT ARM position.
5. APU OFF AGENT ARM Switch
The APU OFF AGENT ARM position will shut down the APU, arm the fire
extinguishing system, and deenergized the APU generator field.
When the switch is in the NORMAL position, the fire extinguishing system
is not armed.
October 02, 2006