MD-11 Flight Crew Operations Manual
k
Warning and Alerting -
Controls and Displays
Warn.30.3
4. MISC Cue Switch - white
When pushed, the MISCELLANEOUS page will appear on the SD. The
MISCELLANEOUS page displays alerts (level 3, 2, and 1 only) and
consequences. The consequences are not grouped with the alerts in the same
manner as the systems page. The MISCELLANEOUS page has maximum of
17 alerts and 17 consequences. When additional pages are required, PRESS
MISC AGAIN TO CONTINUE message will appear at the bottom of the
page.
5. CONFIG Cue Switch - white
Illuminates when an alert related to the flight controls or landing gear appears
on the EAD. Pushing the CONFIG cue switch causes the flight controls
synoptic page to be displayed on the SD and resets the MASTER CAUTION
or MASTER WARNING provided no other alert condition exist that would
illuminate the MASTER CAUTION or the MASTER WARNING lights.
6. FUEL Cue Switch - white
Illuminates when an alert related to the fuel system appears on the EAD.
Pushing the FUEL cue switch causes the fuel synoptic page to be displayed
on the SD and resets the MASTER CAUTION or MASTER WARNING
lights provided no other alert condition exist that would illuminate the
MASTER CAUTION or MASTER WARNING lights.
7. AIR Cue Switch - white
Illuminates when an alert related to the air system appears on the EAD.
Pushing the AIR cue switch causes the air synoptic page to be displayed on
the SD and resets the MASTER CAUTION or MASTER WARNING lights
provided no other alert condition exist that would illuminate the MASTER
CAUTION or MASTER WARNING lights.
8. ELEC Cue Switch - white
Illuminates when an alert related to the electrical system appears on the EAD.
Pushing the ELEC cue switch causes the electrical synoptic page to be
displayed on the SD and resets the MASTER CAUTION or MASTER
WARNING lights provided no other alert condition exist that would
illuminate the MASTER CAUTION or MASTER WARNING lights.
9. HYD Cue Switch - white
Illuminates when an alert related to the hydraulic system appears on the EAD.
Pushing the HYD cue switch causes the hydraulic synoptic page to be
displayed on the SD and resets the MASTER CAUTION or MASTER
WARNING lights provided no other alert condition exist that would
illuminate the MASTER CAUTION or MASTER WARNING lights
October 02, 2006