Loading...
2WA/2NJ/2RK
7-509
U01001/E01001
U01016/E01016
U01019/E01019
Step Check description Assumed cause Measures Reference
1 Resending Function as indicated by
DIS signal is not consistent
with the one of own
machine.
Resend.
2 Checking the transmit start
speed
Line condition is poor.
(Destination unit)
Execute U630 [TX Speed] to
reduce the transmit start
speed. Then, resend the
data.
U630 Exe-
cution
3 Changing the initial value Line condition is poor.
(Own machine)
Change the default value of
the transmit start speed by
executing U630 [TX Speed].
U630 Exe-
cution
Step Check description Assumed cause Measures Reference
1 Resending T1 timeout occurs since
MBF signal is received but
DIS signal is not after
sending EOM signal.
Resend.
2 Checking the transmit start
speed
Line condition is poor.
(Destination unit)
Execute U630 [TX Speed] to
reduce the transmit start
speed. Then, resend the
data.
U630 Exe-
cution
3 Changing the initial value Line condition is poor.
(Own machine)
Change the default value of
the transmit start speed by
executing U630 [TX Speed].
U630 Exe-
cution
Step Check description Assumed cause Measures Reference
1 Resending Command send retrial
times exceeds since signif-
icant signal is not received
after sending CNC signal.
(between own machines)
Resend.
2 Checking the transmit start
speed
Line condition is poor.
(Destination unit)
Execute U630 [TX Speed] to
reduce the transmit start
speed. Then, resend the
data.
U630 Exe-
cution
3 Changing the initial value Line condition is poor.
(Own machine)
Change the default value of
the transmit start speed by
executing U630 [TX Speed].
U630 Exe-
cution