2WA/2NJ/2RK
4-28
(3-2) Detaching and reattaching the transfer belt unit
Procedures
1. Pull out the conveying unit (a).
2. Remove three screws (b) and remove
the conveying rear middle cover (c).
3. Disconnect the connector (d).
Figure 4-32
4. Remove each screw (c) of the rear
transfer holder (b) and front transfer
holder (a).
5. Release each two hooks (e) by the tip
of a flat blade screwdriver through the
square hole (d) and then remove the
rear transfer holder (b) and front trans-
fer holder (a).
Figure 4-33
a
b
b
b
c
d
c
d
d
b
a
e
e
c
d
d
e
e

Table of Contents