EasyManua.ls Logo

Kyocera TASKalfa 8002i

Kyocera TASKalfa 8002i
1627 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2WA/2NJ/2RK
7-581
(4) Phenomenon 1
Condition 1
Condition 2
Phenomenon 2
(5) Abnormal sound from the eject section
Smudges / foreign objects adhesion in the eject section
2 Checking the developer
unit
The developer unit is
faulty.
Replace the developer unit. Detaching
and Reat-
taching the
developer
unit
Step Check description Assumed cause Measures Reference
No Step Cause Measures Reference
for the
measures
1 Cleaning and applying the
grease
The bushing or the gear is
dirty or foreign objects are
on them.
Clean the bushings or the
shafts of DP conveying rollers
1-3 and apply grease to
them.
2 Checking the bushing The bushing is worn down. Replace the bushing.
3 Cleaning and applying the
grease
The drive gear is dirty or
foreign objects are on it.
Clean the drive gears of the
DP conveying motor and the
DP reverse motor and apply
the grease to them.
4 Checking the motor The DP conveying motor
does not engage with the
drive gear.
Reattach the DP conveying
motor or the DP reverse
motor.
Step Check description Assumed cause Measures Reference
1 Cleaning and applying the
grease
The bushing or the gear is
dirty or foreign objects are
on them.
Clean the bushing and the
gear of the eject roller and
apply grease to them.
2 Cleaning and applying the
grease
The shaft is dirty or foreign
objects are on it.
Clean the shaft of the eject
pulley and apply grease to it.
3 Checking the upper/lower
change guides
The shaft is dirty or foreign
objects are on it.
Clean the shafts of the upper/
lower change guides and
apply grease to them.
Step Check description Assumed cause Measures Reference