(18)Image adjusting
Execute the image adjusting in the maintenance mode workflow (Maintenance mode U952 )
1. Input "10871087" using the numeric keypad to enter the maintenance mode.
2. Input "952" using the numeric keypad and press the [Start] key.
3. Select [Execute].
4. Select [Setup] when adjusting the main unit. Select [Setup] after selecting [HIGH ALTITUDE} when installing in the
high altitude more than 1,000m.
*: When adjusting the optional enhancement, select [EH Setup].
5. Select the maintenance mode which is displayed in order from the top, push [Start] key, move to the maintenance
mode.
6. Execute the below setting procedure of the maintenance mode after moving.
7. Press the [Stop] key and back to the original flow after executing.
8. Repeat the procedure 5,6,7 and finish the workflow.
When U952 is not executed, enter the maintenance mode with the numeric keypad in following order and exe-
cute each setting.
(18-1) Set up in a high altitude
When setting up in a high altitude, execute the following.
1.Maintenance mode U140 > [AC Calib] > [Calibration] >
Type: 0 (default), K : ON > [Execute]
Press the [Start] key.
* :When the developer leak happens after setting the above.
Select U140 > [AC Calib] > [Magnification] and then lower the K numeric value.
(18-2) Setting the ID correction operation (Maintenance mode U464)
1.Input "464" using the numeric keypad and press the [Start] key.
2.Select [Calib] > [Execute].
3.Press the [Start] key.
* :Calibration starts.