Loading...
2WA/2NJ/2RK
7-499
(1-11) The beep sounds when the copying or printing is finished.
(1-12) When the data of the A3 or B4 size originals is transmitted, all of it is
transmitted as the A4 size data.
(2) Communication Errors
Error codes are listed on the communication reports, activity report, etc. The codes consist of an error
code indication U followed by a 5-digit number. (The V.34 error is indicated with E of the error code and 5-
digit number)
Regarding the 5-digit number, upper 3 digits indicate error and large classification of cause, lower 2 digits
small classification of cause. The lower 2 digits are 00 for the item not requiring the category.
5 Checking the destination
unit
The modular cable is dis-
connected in the destina-
tion unit if the destination
unit does not receive the
calling.
Request the destination unit
to reconnect the modular
cable.
6 Checking the setting in the
destination unit
The manual reception is
set in the destination unit if
the destination unit does
not receive the calling.
Ask the destination unit to
change the reception set-
tings.
7 Checking the sending con-
tent
When transmitting the data
to the other country, the
communication line is
automatically cut.
Input a pause at the last of
the destination FAX number.
Step Check description Assumed cause Measures Reference
1 Firmware Update The firmware is not the lat-
est version.
Upgrade the fax firmware to
the latest version.
Firmware
Update
Step Check description Assumed cause Measures Reference
1 Checking the settings The receivable size in the
destination unit is A4 / Let-
ter.
Select [B4] or [A3/Ledger]
according to the receivable
size at the Address book reg-
istration display > [i-FAX] >
[Paper size].
2 Checking the settings The receivable size in the
destination unit is A4 / Let-
ter.
Select the condition of the
destination unit when trans-
mitting the data, choose [B4]
or [A3/Ledger] according to
the receivable sizes.
Step Check description Assumed cause Measures Reference