2WA/2NJ/2RK
7-528
(3) Communication Error codes
Error code Contents
U00000/E00000 No response or busy after the set number of redials.
U00100/E00100 Transmission was interrupted by a press of the stop/clear key.
U00200/E00200 Reception was interrupted by a press of the [Stop] key.
U00300/E00300 Recording paper on the destination unit has run out during transmission.
U00430/E00430 Polling request was received but interrupted because of a mismatch in permitted num-
ber.Or, subaddress-based bulletin board transmission request was received but inter-
rupted because of a mismatch in permitted ID in the transmitting unit.
U00431/E00431 An sub address bulletin board transmission was interrupted because the specified sub
address password was not registered.
U00432/E00432 A sub address bulletin board transmission was interrupted because the sub address
password did not match.
U00433/E00433 A sub address bulletin board transmission request was received but data was notpresent
in the sub address box.
U00440/E00440 Sub address confidential reception was interrupted because the specified sub address
password was not registered.
U00450/E00450 The reception was interrupted because the permitted ID and FAX number did not match
in the restricted transmission (password check transmission) in the destination unit.
U00460/E00460 The encryption reception was interrupted because the specified encryption box number
was not registered.
U00462/E00462 Encrypted reception was interrupted because the encryption key for the specifiedencryp-
tion box was not registered.
U00601/E00601 Document jam or the document length exceeds the maximum.
U00613/E00613 Image writing section problem
U00656/E00656 The data was not transmitted due to an error in the modem.
U00690/E00690 System error
U00800/E00800 A page transmission error occurred because of the reception of an RTN or PIN signal.
U00811/E00811 A page reception error remained after retry of transmission in the ECM mode.
U00900/E00900 An RTN or PIN signal was transmitted because of a page reception error.
U01000/E01000 An FTT signal was received for a set number of times after TCF signal transmission at
2400 bps.Or, an RTN signal was received in response to a Q signal (excluding EOP)
after transmission at 2400 bps.
U01001/E01001 Function as indicated by DIS signal is not consistent with the one of own machine.
U01016/E01016 T1 timeout occurs since MBF signal is received but DIS signal is not after sending EOM
signal.
U01019/E01019 Command send retrial times exceeds since significant signal is not received after send-
ing CNC signal. (between own machines)
U01020/E01020 Command send retrial times exceeds since significant signal is not received after send-
ing CTC signal. (ECM)