2WA/2NJ/2RK
7-22
(2-14) Part of the image is not copied
When scanning the second (back) side through the DP
3 Checking the lamp unit
assy (mirror frame A, B).
The mirror has condensa-
tion.
Remove the condensation on
the mirrors of the lamp unit
assy (mirror frame A, B).
Detaching
and Reat-
taching the
lamp unit
4 Checking the ISU The lens has condensa-
tion.
Remove the condensation on
the ISU lens.
Detaching
and Reat-
taching the
lens unit
5 Checking the ISU The glass of the CCD
PWB has condensation.
Remove the condensation on
the CCD PWB glass using a
blower brush
Detaching
and Reat-
taching the
lens unit
6 Executing U411 Each auto adjustment of
the scanner is incorrect.
Execute U411 [Table(Chart
A)].
Executing
U411
7 Checking the ISU The CCD PWB is faulty. Replace the ISU. Detaching
and Reat-
taching the
ISU
8 Checking the engine PWB The connectors or the
FFCs on the engine PWB
are not properly con-
nected. Or the wires, FFCs
or the engine PWB are
faulty.
Reconnect the connectors on
the engine PWB. Then, fix or
replace the wires if they are
pinched by the other part or if
they have any damage.
When the issue is not
resolved after that, replace
the engine PWB.
Detaching
and Reat-
taching the
engine
PWB
9 Checking the main PWB The connectors on the
main PWB are not properly
connected, or the wires or
the main PWB are faulty.
Reconnect the connectors on
the main PWB. Then, fix or
replace the wires if they are
pinched by the other part or if
they have any damage.
When the issue is not
resolved, replace the main
PWB.
Detaching
and Reat-
taching the
main PWB
Step Check description Assumed cause Measures Reference
1 Reloading the original The originals are not prop-
erly set on the original tray.
Reload the original properly.
2 Setting the original size Actual original size and
detected original size are
mismatched.
Set the original size manu-
ally.
3 Changing the Border
Erase function
The Border Erase function
is not properly set. (Setting
is too large.)
Lower the setting of the Bor-
der Erase.
Step Check description Assumed cause Measures Reference