4-5 Adjustment procedures after replacing the maintenance kit
Execute the following procedures after replacing the above maintenance kit.
Execute with the preset in the U952 maintenance mode workflow. (P.6-252)
1. Input "10871087" using the numeric keys to enter the maintenance mode.
2. Input "952" using the numeric keys and press the [Start] key.
3. Select the [Execute].
4. Select the maintenance kit to set.
5. Select the displayed maintenance modes from the top and press the [Start] key to enter the maintenance
mode.
6. After transition, execute the setting steps in the maintenance mode.
7. After executing, press the [Stop] key to go back to the original flow.
Repeat step 5, 6 and 7 and terminate the workflow.
14j0115
MK-6725
ࢫࢱ࣮ࢺ
U119 Setting the drum (Execute)
U140 Developer bias adjustment
(AC Calib> Calibration)
Start
U464 ID correction setting
(Calib > Execute)
U464 ID correction setting
(Calib > Execute)
U127 Clearing the transfer count
(Clear)
U412 Adjusting the uneven density
(Normal Mode)
U251 Clearing the maintenance counter
(Clear)
U410 Adjusting the halftone automatically