2WA/2NJ/2RK
4-29
6. Remove the transfer belt unit (a).
7. Check or replace the transfer belt unit
(a) and then reattach the parts in the
original position.
*: When reattaching the transfer belt unit
(a), observe the precautions in the fol-
lowing.
Insert the protrusion (d) at the bottom of
the transfer belt unit into the square
hole (c) on the conveying base (b).
Mount the transfer belt unit (a) so that
its holders at both ends confront with
the four tension springs (e) on the con-
veying base (b).
8. Execute the following procedures when
replacing the transfer belt unit to the
new unit (a).
1) Execute maintenance mode U127
(Transfer counter clear). (Refer P.6-
84)
2) Execute maintenance mode U464
(Calibration). (Refer P.6-189)
3) Execute maintenance mode U410
(Auto halftone adjustment). (Refer
P.6-170)
Figure 4-34
a
e
e
c
b
d

Table of Contents