2WA/2NJ/2RK
6-189
Contents
Set permission/prohibition of the ID correction operation (calibration). Executes each setting of
the calibration.
Purpose
Execute the calibration setting when an image failure occurs or depending on the user’s request.
Execute Calibration when replacing the maintenance kit.
Execution
1.Press the [Start] key.
2.Select the item to set.
* :The screen for setting is displayed.
Setting: Permission
1.Select [On] or [Off].
* :Initial setting: On(1)
2.Press the [Start] key to set the setting value.
U464 ID correction setting
(Message: Set ID Adjustment Mode)
Items Contents
Permission Permit/Prohibit Calibration
Time Interval Sets the time interval to execute calibration after completing printing.
Mode Calibration execution cycle setting
On/Sleep Out Calibration operation setting (start-up/recovery from sleep mode)
AP/NE Calibration operation setting (AP/NE)
Leaving Time Setting the time to determine whether to execute calibration when recov-
ering from sleep mode
Driving Time Setting the time to determine whether to execute between the paper cal-
ibration from driving time while printing.
Timing Setting the execution timing by drive time
Target Value Setting the target sensor value for the toner thick layer calibration and
light intensity calibration
Calib Executing Calibration
Items Contents
On 1: Permitting Calibration
Off 0: Prohibiting Calibration