EasyManua.ls Logo

Kyocera TASKalfa 8002i - Page 1371

Kyocera TASKalfa 8002i
1627 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2WA/2NJ/2RK
7-511
U01028/E01028
U01052/E01052
U01080/E01080
Step Check description Assumed cause Measures Reference
1 Resending T5 timeout is detected
when sending in ECM
(ECM)
Resend.
2 Checking the transmit start
speed
Line condition is poor.
(Destination unit)
Execute U630 [TX Speed] to
reduce the transmit start
speed. Then, resend the
data.
U630 Exe-
cution
3 Changing the initial value Line condition is poor.
(Own machine)
Change the default value of
the transmit start speed by
executing U630 [TX Speed].
U630 Exe-
cution
Step Check description Assumed cause Measures Reference
1 Resending DCN signal is received
after sending RR signal
(ECM)
Resend.
2 Checking the transmit start
speed
Line condition is poor.
(Destination unit)
Execute U630 [TX Speed] to
reduce the transmit start
speed. Then, resend the
data.
U630 Exe-
cution
3 Changing the initial value Line condition is poor.
(Own machine)
Change the default value of
the transmit start speed by
executing U630 [TX Speed].
U630 Exe-
cution
Step Check description Assumed cause Measures Reference
1 Resending PIP signal is received after
sending PPS and NULL
signals.
Resend.
2 Checking the transmit start
speed
Line condition is poor.
(Destination unit)
Execute U630 [TX Speed] to
reduce the transmit start
speed. Then, resend the
data.
U630 Exe-
cution
3 Changing the initial value Line condition is poor.
(Own machine)
Change the default value of
the transmit start speed by
executing U630 [TX Speed].
U630 Exe-
cution

Table of Contents