EasyManua.ls Logo

Kyocera TASKalfa 8002i - Page 1373

Kyocera TASKalfa 8002i
1627 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2WA/2NJ/2RK
7-513
U01096/E01096
U01097/E01097
U01100/E01100
Step Check description Assumed cause Measures Reference
1 Resending DCN signal or invalid com-
mand is received at phase
D during transmission.
Resend.
2 Checking the transmit start
speed
Line condition is poor.
(Destination unit)
Execute U630 [TX Speed] to
reduce the transmit start
speed. Then, resend the
data.
U630 Exe-
cution
3 Changing the initial value Line condition is poor.
(Own machine)
Change the default value of
the transmit start speed by
executing U630 [TX Speed].
U630 Exe-
cution
Step Check description Assumed cause Measures Reference
1 Resending The preset number of com-
mand retransfers was
exceeded after transmis-
sion of an RRsignal or no
response.
Resend.
2 Checking the transmit start
speed
Line condition is poor.
(Destination unit)
Execute U630 [TX Speed] to
reduce the transmit start
speed. Then, resend the
data.
U630 Exe-
cution
3 Changing the initial value Line condition is poor.
(Own machine)
Change the default value of
the transmit start speed by
executing U630 [TX Speed].
U630 Exe-
cution
Step Check description Assumed cause Measures Reference
1 Request for resending Function indicated by DCS
signal is not consistent
with the one of own
machine.
Request resending.
2 Changing the initial value Line condition is poor.
(Own machine)
Change the reception speed
by executing U630 [RX
Speed].
U630 Exe-
cution

Table of Contents