EasyManua.ls Logo

Kyocera TASKalfa 8002i - Page 1376

Kyocera TASKalfa 8002i
1627 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2WA/2NJ/2RK
7-516
U01143/E01143
U01155/E01155
U01160/E01160
U01162/E01162
Step Check description Assumed cause Measures Reference
1 Checking the settings DCN signal is received
after sending FTT signal.
Set the G3 reception cable
equalizer in U650 [Reg G3
RX Eqr]. (Initial setting:
0dBm)
U650 Exe-
cution
Step Check description Assumed cause Measures Reference
1 Request for resending DCN signal is received
after sending SPA signal.
(simplified protocol)
Request resending.
2 Changing the initial value Line condition is poor.
(Own machine)
Change the reception speed
by executing U630 [RX
Speed].
U630 Exe-
cution
Step Check description Assumed cause Measures Reference
1 Request for resending Maximum transmission
time per line is exceeded
while receiving message.
Request resending.
2 Changing the initial value Line condition is poor.
(Own machine)
Change the reception speed
by executing U630 [RX
Speed].
U630 Exe-
cution
Step Check description Assumed cause Measures Reference
1 Request for resending Maximum transmission
time per line is exceeded
while receiving message.
Request resending.
2 Changing the initial value Line condition is poor.
(Own machine)
Change the reception speed
by executing U630 [RX
Speed].
U630 Exe-
cution