2WA/2NJ/2RK
4-15
9. Release two hooks (a) and remove the
cover (b).
Figure 4-13
10. Release the hook (a) and remove the
PF separation pulley (b)(left) from the
shaft.
11. Clean or replace the PF forwarding pul-
ley (left), PF paper feed pulley (left) and
PF separation pulley (left).
12. Reattach the PF forwarding pulley (left),
PF paper feed pulley (left) and PF sepa-
ration pulley (left) in the original position
of the primary paper feed unit.
*: Attach them while checking the color of
the collar.
PF forwarding pulley (left) (Collar:
white)
PF paper feed pulley (left) (Collar:
white)
PF separation pulley (left) (Collar:
black)
Figure 4-14
a
b