4. Remove the right hinge cover (a).
5. Turn the adjusting screw (b) at the rear
side of the right hinge to adjust the DP
position.
For copy example 1:
Turn the adjusting screw counterclock-
wiseand move the DP to the rear side.
For copy example 2:
Turn the adjusting screw clockwise and-
move the DP to the front side.
Amount of change per scale: Approx. 1
mm
6. Make a test copy.
7. Repeat the steps above until the gap
ofthe leading edge falls within the Refer
encevalues.
8. After adjustment is completed, retight-
entwo screws that have been loosened
in step 3.
Figure 4-327
a
b
14j0513