2WA/2NJ/2RK
6-179
Error codes list
Setting: On/Off Config
1.Select the item to set.
* :Initial setting: On
* :Automatically set to on after completing correction.
2.Press the [Start] key to set the setting value.
Completion
Press the [Stop] key.
* :The screen for selecting a maintenance item No. is displayed.
Display Contents Display Contents
S001 Patch is not detected SFFF Other scanner error
S002 Original position shift in the main
scanning direction
EFFF Other engine error
S003 Original position shift in the sub-
scanning direction
C001 Controller error
S004 Original skew error CFFF Other controller error
S005 Original type error
Items Contents
On Enable the uneven density correction