2WA/2NJ/2RK
7-64
8 Checking the wire The connectors are not
properly connected or the
wire is faulty.
Clean the terminal of the fol-
lowing wire connectors and
reinsert the connectors.
Replace the wire when it has
no continuity. • Main high-
voltage PWB - Engine PWB
Wiring dia-
gram
9 Replacing the high-volt-
age PWB
The high-voltage contact of
the high-voltage PWB is
deformed or damaged.
Replace the high-voltage
PWB.
Detaching
and Reat-
taching the
main high-
voltage
PWB
10 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB. Detaching
and Reat-
taching the
engine
PWB
Step Check description Assumed cause Measures Reference