ipLDK-60 Issue 2.0
Admin Programming Manual July, 2010
117
PGM
180
Flex
Btn
Description Default Values
Transfer Recall
Timer
7 This parameter sets the duration transferred calls ring the intended receiver before
recalling the transferring station.
030 seconds 000 ~ 300 in 1
second increments
ACNR Delay
Timer
8 When no CO line is available for an ACNR attempt, this parameter sets the delay
before ACNR reattempts access to a CO line. This will not affect the retry counter.
030 seconds 000 ~ 300 in 1
second increments
ACNR No
Answer Timer
9 This parameter sets the duration of ringback tone before an ACNR attempt
terminates, the call disconnects and the retry counter increments.
30 seconds 01 ~ 50 in 1 second
increments
ACNR Pause
Timer
10 This parameter sets the time between ACNR attempts, at expiration the ipLDK
attempts ACNR.
030 seconds 005 to 300 in 1
second increments
ACNR Retry
Counter
11 This parameter determines the number of attempts the system will make for a given
ACNR request. After the assigned number of attempts, ipLDK cancels the ACNR
request.
03 01 ~ 30
ACNR No Tone
Retry Counter
12 This parameter determines the maximum number of times ACNR attempts to secure
a CO line. If a CO line is not seized (all lines busy or out-of-service), ipLDK cancels
the ACNR request.
1 1 ~ 9
ACNR Tone
Detect Timer
13 This parameter sets the duration the system will monitor the CO line for valid call
progress tones. If ipLDK detects busy or reorder tone or the timer expires, the
attempt terminates, the CO line disconnects and the retry counter increments.
030 seconds 000 ~ 300 in 1
second increments
Automatic CO
Release Timer
14 This parameter sets the duration the system will wait for a user to dial on an outgoing
CO line call. If the timer expires, the call attempt terminates and the station receives
error tone.
030 seconds 020 ~ 300 in 1
second increments
CCR Inter-digit
Timer
15 This parameter sets the duration the system will wait between dialed digits for a CCR
or DISA/DID CO call. After the timer expires, the call is routed based on the
received digits.
030 (3 seconds) 000 ~ 255 in 100 mill-
second increments
CO Call Drop
Warning Timer
16 This parameter sets the duration a Prepaid or Unsupervised Conference call remains
connected after receiving Call Drop Warning Tone. After this timer expires, the call
10 seconds 00 ~ 99 in 1 second
increments