– 205 –
CHAPTER 3 System Messages
0-C: Reset Interrupt
This message displays when the processor is reset due to a failure in the system.
Self-CPU Restart Information
Mate-CPU Restart Information
(FF H: not mounted)
Related-call Release Result
Reference: See section 4.7.1 on page 640, for the repair procedure.
Default Alarm Default Grade Grade Modified Lamp Modified
MN 3
1: XXXX XX00 XXXX XX00 2: XXXX 0000 0000 0000 3: 0000 0000 0000 0000
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b7 b6 b5 b4 b3 b1 b0
b7 b6 b5 b4 b3 b1 b0
b7 b0
1 2 3
4
b0: 0/1 = -/Monitor Restart
b1: 0/1 = -/Phase 2 Executed (LP only)
b3: 0/1 = -/Initialization
b4: 0/1 = -/Data Copy Restart executed (for Dual-CPU system only)
b5: 0/1 = -/MB Control
b6: 0/1 = Program Load not executed/executed
b7: 0/1 = ACT/STBY (active system indication after restart)
1
b0: 0/1 = -/Monitor Restart
b1: 0/1 = -/Phase 2 Executed (LP only)
b3: 0/1 = -/Initialization
b4: 0/1 = -/Data Copy Restart executed (for Dual-CPU system only)
b5: 0/1 = -/MB Control
b6: 0/1 = Program Load not executed/executed
b7: 0/1 = ACT/STBY (active system indication after restart)
2
b7: 0/1 = Call Release Processing after restart ->Normal End/Abnormal
End
3