ā 904 ā
CHAPTER 7 Maintenance Commands
RPID : Remove of Pad Lock ID Data
1. Functional Outline
This command is used to release the PAD LOCK ID Code setting of each analog/Dterm station by the PCPro
operation.
2. Parameters
Input Data
TN: Tenant Number
Enter the Tenant Number in which the target station belongs.
STN: Station Number [Max. 6 digits]
Designate the station number whose PAD LOCK ID Code setting is to be re-
leased.
Output Data
PID: PAD LOCK ID Code
RSC: Route Restriction Class [0-15]
SFC: Service Feature Class [0-15]
Note: It is not available to display and list up the ID codes on the PCPro screen.
Buttons
Get: Get information for the PAD LOCK ID Code assigned to the station/tenant.
Del.: Delete information for the PAD LOCK ID Code assigned to the station/tenant.
Exit: Exit this command.