EasyManua.ls Logo

NEC UNIVERGE SV8500 - S Module Group down Failure

NEC UNIVERGE SV8500
975 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
– 227 –
CHAPTER 3 System Messages
1-S: Module Group Down Failure
This message displays when a fault of the speech path system has occurred in a specific Module Group. The
specific Module Group is placed into make-busy state.
MG number of fault detection
Kind of failure
Speech Path/Clock System
Reference: See Chapter 5 TSW Replacement: 1-IMG or TSW Card Replacement Procedure: 4-IMG for the
circuit card replacement procedure.
Default Alarm Default Grade Grade Modified Lamp Modified
MJ 3
1: XXXX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b7 b0
b7 b6 b5 b4 b3 b2 b1 b0
b7 b1 b0
1 2
3
b0: 0/1 = Even-numbered MG/Odd-numbered MG
1
b0-b7: 00H/01H = -/ACT side TSW fault
2
b0: ACT side speech path
0/1 = System 0/System 1
b1: ACT side clock
0/1 = System 0/System 1
3

Table of Contents

Other manuals for NEC UNIVERGE SV8500

Related product manuals