– 235 –
CHAPTER 3 System Messages
3-C: C-Level Infinite Loop (Temporary)
This message displays when C-Level program is detected as abnormal by the Port Microprocessor (PM)
mounted on an LC/TRK card. If the failure occurs less than 15 times/hour, and a B-monitor/Initial restart
executes as the result, the failure is judged as temporary and this message is created.
Faulty Circuit Card Mounting
Location
PM Restart Type
Note: B-monitor Restart: Ports whose link has already been established remain connected. Ports processing a
call-origination may be released.
Initial Restart: All ports on the circuit card are forcibly released to be placed in idle state.
Default Alarm Default Grade Grade Modified Lamp Modified
SUP 1
1: XX0X 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b7 b6 b5 b4 b3 b2 b1 b0
b7 b0
1 2
b0-b4: Group
b5-b6: Unit (0-3)
b7: Module Group (0/1)
1
b0: 0/1 = B-monitor/Initial Restart Note
2