CHAPTER 3 System Messages
0-E: C-Level Infinite Loop
C-Level infinite loop is a state where a clock-level program, running under clock interrupt disable state, is in an
infinite loop. This message displays when the counter value to check the normality of the processing has become
abnormal.
Self-CPU Restart Information after
clock fault occurrence
Mate-CPU Restart Information
NMI Factor
Reference: See Section 4.7.1,
Control System Fault - Fault Occurs
Intermittently on ACT side, for the repair procedure.
Default Alarm Default Grade Grade Modified Lamp Modified
SUP 2
0-E C-Level Infinite Loop
1: XXXX XXXX XXXX XXXX 2: XXXX XXXX XXXX XXXX 3: XXXX XXXX XXXX XXXX
4: XXXX XXXX XXXX XXXX 5: XXXX XXXX XXXX XXXX 6: XXXX XXXX XXXX XXXX
7: XXXX XXXX XXXX XXXX 8: XX00 0000 0000 0000 9: 0000 0000 0000 0000
b7 b5 b4 b3 b0
b7 b5 b4 b3 b0
b7 b6 b5 b4 b3 b2 b1 b0
1 2 3 4
5 6
7
8
8
b0: 0/1 = -/Monitor Restart
b3: 0/1 = -/Initialization
b4: 0/1 = -/Data Copy Restart (for Dual-CPU system only)
b5: 0/1 = -/MB Control
b7: 0/1 = ACT/STBY (active system indication after restart)
1
b0: 0/1 = -/Monitor Restart
b3: 0/1 = -/Initialization
b4: 0/1 = -/Data Copy Restart (for Dual-CPU system only)
b5: 0/1 = -/MB Control
b7: 0/1 = ACT/STBY (active system indication after restart)
2
b0: 0/1 = -/Reset by Power On
b1: 0/1 = -/Watchdog Timer timeout
b2: 0/1 = ISAGT is mounted/ISGAT is not mounted
b3: 0/1 = -/OSC clock interrupt on ISGAT
b4: 0/1 = -/IO parity Alarm
b5: 0/1 = -/IO ready Alarm
b6: 0/1 = -/External NMI
3