– 589 –
CHAPTER 5 Operation Procedure for System with PIR
2.7.2 Procedure for Replacing #0 Side of AC/DC Power Unit
STEP 1 Turn the power switch OFF for #0 side of AC/DC power unit.
STEP 2 Unlock the #0 side of AC/DC power unit.
STEP 3 Use the handle to pull the #0 side of AC/DC power unit frontward.
Note: FANs constantly turn as long as power units are inserted. Be careful not to touch the FANs.
STEP 4 Slide in the new AC/DC power unit. Check that the OPE lamp light is ON and the FAN is turn-
ing.
STEP 5 Slide the LOCK key downward to lock the unit.
STEP 6 Turn the power switch ON for #0 side of AC/DC power unit.
STEP 7 Repeat the above steps for #1 side of AC/DC power unit if necessary.
Turn the switch to left side (OFF)
Power Switch for #0
ON
OFF
Slide the LOCK key up
to unlock the unit.
LOCK key for #0
Front View