– 50 –
CHAPTER 2 Operations of SV8500 Server
3.3 Initialization by PCPro Tools
The following initialization type is available.
• Office Data Load & Program Load (& OS Load) Initial
STEP 1 Run PCPro Tools on a PC.
STEP 2 Select “System Control” and then click “Execute” button.
STEP 3 Select “System Reboot” from the list box, and then click “Execute” button.
• Initialization starts.
• PCPro is automatically placed in logout state.
Note: For the detail, refer to “UNIVERGE SV8500 Command Manual“.
STEP 4 Make sure that the following lamps light green on the EMA card.
STEP 5 Log into the system again from the PCPro.
STEP 6 Set the current date and time from the PCPro. (Refer to How to Adjust Date and Time.)
STEP 7 Release the indicated alarm. (Refer to How to Stop Alarm Indications.)
Lamp name Status
PWR Lights green
LINK Lights green
ACT Lights green