– 214 –
CHAPTER 3 System Messages
0-I: Mate CPU Failure
This message displays when a fault, such as the Clock down or C-Level infinite loop error, has occurred.
Mate-CPU Restart Information
Reference: See Control System Fault - Fault Occurs Intermittently on ACT side, Control System Fault - STBY
Side Is Faulty for the repair procedure.
Default Alarm Default Grade Grade Modified Lamp Modified
SUP 3
1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b7 b3 b2 b1 b0
1
b0: 0/1 = -/CPU clock down
b1: 0/1 = -/C-Level infinite loop
b2: 0/1 = -/Memory error, Parity alarm
b3: 0/1 = -/Emergency Timer Overflow