EasyManua.ls Logo

NEC UNIVERGE SV8500 - MBRT Make-Busy of Route

NEC UNIVERGE SV8500
975 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
– 880 –
CHAPTER 7 Maintenance Commands
MBRT: Make-Busy of Route
1. Functional Outline
This command is used to assign IDLE/BUSY status for all the trunks in the route designated.
2. Parameters
Input data
RT: Route Number of the external route/internal route. Table 7-1 provides the meaning of
the internal route number.
MB: Make-Busy Information [0-1]
0=Make Idle
1=Make Busy
Table 7-1 Route Number Explanation
DATA MEANING DATA MEANING
901 Attendant/Desk Console 902 Originating Register Trunk
903 Incoming Register Trunk 904 MF Receiver
905 Sender Trunk DP/PB 906 PB Receiver for Automated Attendant Service
907 AMP 908 Not used
909 Three-Way Conference Trunk 910-912 Not used
913 Three-Way Conference Trunk for ATTCON 914 Not used
915 Night Attendant Console 916 MFC Register
917 MFC Sender 918 Not used
919-926 Modem 927, 928 Not used
929 Data Signaling Trunk-Option 930 Rate Adapter Conversion Trunk
931-947 Not used

Table of Contents