EasyManua.ls Logo

NEC UNIVERGE SV8500 - Z both MUX Clock Failure

NEC UNIVERGE SV8500
975 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
– 423 –
CHAPTER 3 System Messages
23-Z: Both MUX Clock Failure
This message displays when the MUX card has a clock failure in both of the dual systems.
MUX card location
Scan Data 1
Scan Data 2
Reference: See Chapter 5 MUX Replacement: 1-IMG or MUX Replacement: 4-IMGfor the circuit card
replacement procedure.
Default Alarm Default Grade Grade Modified Lamp Modified
MN 3
1: XXXX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b7 b2 b1 b0
b7 b3 b2 b1 b0
b7 b3 b2 b1 b0
1
2
3
b0-b1: Unit number
b2: MG number
1
Scan Data 1:Details on clock alarm information (ACT mode)
b1: 0/1 = -/FH failure for 2M PCM Highway
b2: 0/1 = -/CLK failure for 2M PCM Highway
b3: 0/1 = -/4M CLK failure for PM
2
Scan Data 2:Details on clock alarm information (STBY mode)
b1: 0/1 = -/FH failure for 2M PCM Highway
b2: 0/1 = -/CLK failure for 2M PCM Highway
b3: 0/1 = -/4M CLK failure for PM
3

Table of Contents

Other manuals for NEC UNIVERGE SV8500

Related product manuals